Keperluan Nitrogen Semasa Brazing

Is nitrogen a must while brazing AC lines?

 I have an R410A unit and I've read that an inert gas must be used to sweep the lines while brazing due to the r410a's ability to move the oxidation through the system than compared to an R22. Most people prefer nitrogen from what I've been reading, but it is becoming too hard or too expensive for me to get it.
I do have an air compressor and the air seems pretty dry. I have a filter from the factory on the liquid line of the condensor and I'm installing a moisture indicator as well.

I've heard that some still don't purge the lines if using a filter, bad idea? I can't imagine the oxidation to be that large and the filter would likely trap it and not clog the filter.

Thanks for the help!

 

failing to purge a 410a system with nitrogen before/during brazing wont necessarily cause a problem but increases the chance of a problem..the filter/drier in the liquid line will catch the "flakes" that form on the inside of the pipe and circulate through the system but even if you locate the drier near the indoor coil,you still have the solder joint at the outlet of the drier who's flakes wont be captured by the drier screen because they are downsteam of the body of the drier...those flakes could clog the strainer inside the txv,or otherwise affect the txv...i dont know why 410a systems are more prone to problems from failing to purge while brazing but i've been told that either the refrigerant itself or the "poe"oil in the compressor has a greater attraction to moisture than r-22 systems and their type oil..therfore doing everything by the book is more important on a 410a system,such as installing a large liquid drier [thats rated for puron],,purging with nitrogen while brazing,and evacuating system thoroughly before charging.......the flakes produced while brazing without nitrogen are caused by the presence of oxygen,not moisture.. nitrogen is basically air without the oxygen and moisture...it doesnt require very much nitrogen to purge the system,,just need to have a LITTLE pressure going in while leaving the other port open so it can flow without building any pressure that could cause solder joint leak from nitrogen exiting systen through the solder joint while brazing.....also be sure to take pressure and temperature readings while charging,,and charge per mfr recommendations....usually 10-12 deg "subcooling" is required...dont just add puron until the line gets cold........dan

 

http://answers.yahoo.com/question/index?qid=20090704064250AAXCiYZ 

 

Istilah HVAC / PPU / RAC

HVAC - Heating, Ventilation Air Conditioning.
PPU - Penyejukan dan Penyamanan Udara
RAC - Refrigeration and Air Conditioning
 
p/s ~ Bantuan dari pemilik http://sejukpeti.blogspot.com/

Tips Kebocoran air Bagi Aircond Split Unit

Adalah sangat menjengkelkan apabila kita mempunyai ac split sering mengalami kebocoran air pada indoornya.Selain cat dinding kita menjadi berwarna aneh,apabila airnya jatuh dan masuk ke dalam alat elektronik kita semisal komputer dan TV akan membuat kita merogoh kocek lebih dalam.

Untuk hal - hal tersebut di atas berikut ini akan saya coba berikan Tips2 untuk mengatasinya :

1. Bila anda sudah menjadwalkan secara rutin pemeriksaan dan service AC,anda bisa mengingatkan kepada teknisi yang melakukan pekerjaan pembersihan untuk membongkar penampungan air AC untuk membersihkan kotoran yang berbentuk lendir dan lumpur,kemudian menyemprot saluran pembuangan air (drain)dengan air atau udara.pekerjaan-pekerjaan tadi hanya boleh dilakukan oleh tenaga terlatih dan berpengalaman,jadi anda jangan mengerjakannya sendiri.




2. Secara Rutin anda dapat melakukan sendiri pembersihan filter udara yang terdapat di indoor unit,mintalah kepada teknisi anda untuk menunjukan cara untuk mencabut dan memasang filter udara tersebut.

Demikian tips untuk mengatasi kebocoran air pada indoor ac split dari saya,semoga dapat bermanfaat bagi anda semuanya. selamat mencoba

Copy dari : http://yuzz-teknik.blogspot.com/2009/04/tips-perbaikan-kebocoran-air-pada-ac.html

Maksud SuperHeat

Penjelasan

Definisi dari Superheat adalah differensial temperature antara temperature actual dengan temperature jenuh.yang di maksud dengan temperature actual adalah temperature yang diambil melalui pengukuran langsung dengan menggunakan thermometer baik yang digital maupun thermometer analog.sedangkan yang disebut termperature Jenuh(saturated temperature)adalah temperature hasil conversi dari pengukuran tekanan refrigerant yang dapat dibaca langsung dari manipold gauge atau dengan menggunakan table converse pressure dan temperature yang bisa kita temukan dikemasan refrigerant atau kita download msdsnya (beda merek refrigerant mempengaruhi temperature konversinya).

Contoh : refrigerant R 22
bila temperature actual didapatkan 7oc
Tekanan Refrigerant 60 psig ; bila di konversi ke temperature adalah sekitar 4 oc.
MAka seperheatnya adalah : Actual temp. 7oc – saturated temp. 4 oc. = 3 oc

Kegunaan Superheat

Mengapa kita harus mengetahui superheat?superheat sangat vital sekali di dunia refrigerasi,karena salah satu penyebab kerusakan compressor adalah superheat yang terlalu kecil atau hamper sama dengan Nol.superheat terlalu kecil biasanya diakibatkan oleh penggunaan txv terlalu besar ukurannya(Atau tidak di setting)adan txv yang rusak.

Cara pengukuran superheat sangat mudah sekali.pertama-tama kita sediakan alat-alat yang akan dipergunakan untuk mengukur superheat.alat yang kita butuhkan adalah sebuah manipold gauge yang baik dan sebuah thermometer(dianjurkan mengunakan thermometer digital yang mempunyai probe)

Copy dari http://yuzz-teknik.blogspot.com/

Wednesday, 27 February 2013

Setting email Gmail Menggunakan Outlook

Tools > Accounts>

 internet account

Add>mail

Incoming mail POP3

pop.gmail.com

smtp.gmail.com

 internet account

Properties

Tab General

Tab Advance

out SMTP 465

in POP3 995

Tik This server require SSL



Leak Detection Foam

10620
Leak shooter search-spray
Contents 375 g

A real hit for any service man to shoot for leaks on pressurised tubes i.e. systems. Easy application; just spray strongly any pressurised lines with Leaky-Shooter. Bubbles will occur immediately on leaky systems.

No danger!

Index ~ Laman Peti Sejuk sejukpeti blogspot dot com

Prinsip Sistem Penyejukan

NR-B261M Schematis Diagram

Kenapa peti sejuk boleh rosak?

Panduan Memilih @ Membeli Peti Sejuk Baru Atau Terpakai

Tip jimat elektrik di kediaman anda...

Laman web berkenaan peti sejuk...

Panduan Penjagaan Peti Sejuk Rumah 

membaiki peti sejuk 2 pintu - samsung

Menyimpan pemampat jika tidak digunakan dalam jangka masa yang lama.

Peti sejuk 3 pintu, frost pada bahagian freezer..

lokasi Defrost thermostat

Masalah Peti Sejuk dan Alternatif Penyelesaiannya..


Peti Sejuk Ada "Curent" Pada Body nya..

Bagaimana saya mengira saiz atau kapasiti bagi penyaman udara bagi bilik saya? 2. Jenis penyaman udara yang bagaimana harus saya pertimbangkan? 3. Bagaimana kecekapan tenaga diukur? 4. Bagaimanakah penjagaan unit selepas pemasangan? 5. Berapa lamakah unit penyaman udara tersebut boleh bertahan sebelum ianya diselenggara secara major? (Major service)

Mari Mengenal Komponen-komponen peti sejuk rumah..

Membaiki Kerosakan Pada Komponen Peti Sejuk..

Pemampat peti sejuk domestik..

Basic Cycle For Refrigeration @ Kitaran Asas Sistem Penyejukbekuan...